# 固态功率控制器动态参数测试系统 — 开发文档
> 版本 v1.3 更新:**2026-07-08 14:58:50 +08:00** 技术栈:**C# + WPF + .NET 8** 口径:**以当前仓库代码为准**
>
> 本文档描述当前仓库的真实结构、配置方式、核心流程和维护约定。
> 若文档与代码冲突,以代码实现为准,并应同步回写本文档。
---
## 0. 开发约束
对本项目进行新增、修改、排障时,默认遵守以下原则:
1. **分层隔离优先**UI 只依赖 ViewModel / Service / Logic不直接依赖具体设备驱动。
2. **接口先行**SSPC、电源、负载、DAQ、安全 DIO 一律经 `SSPCTester.Devices.Interfaces` 暴露,真假驱动由配置决定。
3. **按设备粒度切换 Mock/Real**:当前不再是“一个全局 `MockMode` 管全部设备”,而是每类设备都有自己的 `UseMock`
4. **配置分层加载**:程序先读内置默认值,再读 `appsettings.json`,最后读 `%LOCALAPPDATA%\SSPCTester\settings.json`
5. **测试态独占**:进入测试后只展示当前项目,禁止切换其他项目,设备连接由测试态独占。
6. **文档随代码更新**:涉及接口、项目结构、运行方式、持久化格式变化时,要同步更新本文档。
---
## 1. 项目背景
### 1.1 被测对象
固态功率控制器SSPC用于智能配电场景。本项目按 **24 路** 输出通道建模,通过软件控制每路导通/关断,并测量:
- 基础通断状态
- 开启/关断曲线与时间参数
- 功率损耗与效率
- 保护功能测试结果
### 1.2 当前测试台硬件
| 部件 | 型号 | 作用 | 当前代码状态 |
|---|---|---|---|
| 工控机 | Windows x64 | 运行 WPF 主程序 | 已支持 |
| 被测件 SSPC | 24 路 | 控制 24 路导通/关断 | 已有 `SspcModbus` |
| 程控电源 | UDP5080-100 | 输入端电压/电流读取、输出开关控制 | 已有真实驱动 |
| 可编程负载 | IT8733P / IT8702P | 输出端电压/电流/功率读取、输入开关控制 | 已有真实驱动 |
| 高速采集卡 | PCIe8586 | 曲线波形采集 | 已有 `Pcie8586Daq` |
| 安全 DIO 卡 | PCI2312 | 急停输入读取、报警灯输出控制 | 已有 `Pci2312SafetyDio` |
| 示波器 | Tektronix MDO3024 | 线下校准基准 | 不纳入软件控制 |
### 1.3 当前实现事实
- SSPC 24 路通过 **3 个 Modbus 模块 × 每模块 8 路** 映射。
- 采集卡实现已经统一为 **PCIe8586**,不再使用旧文档中的 `PCIe9318` 命名。
- 真假设备切换已经演进为 **每类设备独立 `UseMock`**
- 主程序启动后会按配置自动连接 SSPC、电源、负载、DAQ、PCI2312。
- 新增设备安全监控链路:后台轮询 PCI2312 急停输入,触发后接通报警输出,并向 SSPC、电源、负载发送安全关断指令。
- 根目录脚本 `run.ps1` / `publish.ps1` 已是当前标准运行入口。
---
## 2. 当前功能范围
主流程如下:
```text
新建/打开项目
-> 填写项目信息 / 勾选测试项
-> 进入测试态
-> 执行基础测试 / 曲线测试 / 功率损耗 / 保护功能
-> 生成 PDF / Word 报告
```
### 2.1 四大模块
| 模块 | 当前实现 | 状态 |
|---|---|---|
| 基础测试 | 24 路逐路开/关、读电压电流、判定稳态关断 | 已实现 |
| 开启与关断曲线 | 支持开通/关断波形采集、指标计算、独立曲线视窗、波形落盘 | 已实现 |
| 功率损耗 | 使用 UDP5080 读输入端IT87xx 读输出端功率/电压/电流 | 已实现 |
| 保护功能 | 固定保护项、自动获取/人工观测数据记录、人工判别结果 | 已实现 |
### 2.2 设备安全与急停报警
当前代码新增了独立于“保护功能测试页”的**运行时设备安全链路**
- 硬件连接:`PCI2312` 通过厂商 `PCI2312_64.dll` 以 P/Invoke 方式接入,使用 DI 通道读取急停状态,使用 DO 通道控制报警灯。
- 后台监控:`SafetyMonitorService.Start()` 在主窗口初始化后启动,按 `Devices:Pci2312:PollIntervalMs` 周期轮询急停输入。
- 硬件急停:当配置的 DI 通道达到有效电平时,程序写入报警 DO并依次执行 SSPC 全通道关断、电源输出关闭、负载输入关闭。
- 软件急停:主窗口顶部“报警急停”按钮调用 `TriggerSoftwareEmergencyAsync()`,走同一套报警灯和设备关断链路。
- 状态重置:报警灯点亮后按钮变为“状态重置”。若硬件急停 DI 仍有效重置会被拒绝DI 复位后才关闭报警输出并恢复监控状态。
控制链路如下:
```text
PCI2312 DI 急停输入 / UI 软件急停按钮
-> SafetyMonitorService
-> PCI2312 DO 报警灯输出
-> ISspc.TurnOffAsync(1..24)
-> IPowerSupply.OutputAsync(false) // UDP5080 :OUTput OFF
-> ILoad.InputAsync(false) // IT8702P INP OFF
-> UI 状态、日志和报警灯图标同步刷新
```
注意:这是软件侧联动安全链路,用于快速下发关断和报警指令;现场仍应保留硬件级急停/互锁作为最终安全边界。
### 2.3 指标口径
当前计算与判定主要围绕以下指标:
- `1.1` 开启时间:到达输入电压 90% 的时间
- `1.2` 关闭时间:下降到输入电压 10% 的时间
- `1.5` 上升/下降时间10%~90% 或 90%~10% 时间
- `1.9` 电压降:`Vin - Vout`
- `1.10 / 1.13` 功率损耗、效率
- `1.14+` 保护功能相关触发条件、实测/观测值与人工判别结果
阈值定义和最终判断以 `Project.CurveThresholds` 与各页结果模型为准。
---
## 3. 技术栈
| 用途 | 当前选型 | 说明 |
|---|---|---|
| UI | WPF + .NET 8 | `net8.0-windows`x64 |
| MVVM | `CommunityToolkit.Mvvm` | `ObservableObject` / `RelayCommand` |
| 配置 | `Microsoft.Extensions.Configuration` | JSON + 用户设置覆盖 |
| DI / Host | `Microsoft.Extensions.Hosting` | 启动时装配所有服务 |
| Modbus | `NModbus` | SSPC 串口控制 |
| 串口 | `System.IO.Ports` | SSPC/部分设备底层通信 |
| TCP Socket | `System.Net.Sockets.TcpClient` | UDP5080 / IT87xx SCPI-RAW 通信 |
| 原生驱动 | P/Invoke + 厂商 DLL | PCIe8586 / PCI2312 接入 |
| 波形绘制 | `ScottPlot` / `ScottPlot.WPF` | 曲线页与报告插图 |
| 报告 | `QuestPDF` + `DocumentFormat.OpenXml` | PDF 与 Word 双实现 |
| Web 预览 | `Microsoft.Web.WebView2` | 报告页 PDF 预览 |
| 日志 | Serilog | Debug + 文件输出 |
---
## 4. 解决方案结构
### 4.1 分层
```text
UI (WPF / XAML / ViewModel)
-> Logic (测试流程 / 计算 / 报告 / 存储)
-> Devices.Interfaces (统一设备接口)
-> Devices.Drivers.Mock / Real (具体驱动)
```
依赖方向始终是 **上层只依赖下层抽象**
例如 UI 只拿到 `ISspc`,不直接感知背后是 `MockSspc` 还是 `SspcModbus`
### 4.2 当前解决方案
```text
SSPCTester.sln
├── SSPCTester.UI/ # WPF 主程序(启动项)
│ ├── Views/ # 页面与窗口
│ ├── ViewModels/ # MVVM 视图模型
│ ├── Controls/ # 自定义控件(含曲线控件)
│ ├── Resources/ # Tokens / Controls / Icons
│ ├── Converters/ # 状态与颜色转换
│ └── Services/ # 用户设置、应用配置等
├── SSPCTester.Logic/ # 业务层
│ ├── Testing/ # 测试模块与运行器
│ ├── Calculation/ # 曲线/功率计算纯函数
│ ├── Report/ # PDF/Word 报告实现
│ ├── Storage/ # 项目与波形持久化
│ └── Models/ # 项目、结果、阈值、枚举
├── SSPCTester.Devices/ # 设备抽象与驱动
│ ├── Interfaces/ # ISspc / IPowerSupply / ILoad / IDaq / ISafetyDio
│ ├── Drivers/Mock/ # Mock 驱动
│ ├── Drivers/Real/ # 真设备驱动
│ ├── Drivers/ConfigurableDevices.cs # 按设备切换 Mock/Real
│ ├── Protocol/ # 协议辅助
│ └── Config/ # 设备配置模型
├── SSPCTester.Tests/ # xUnit 测试
├── SSPCTester.Seed/ # 示例项目/种子数据生成
└── Docs/PCIe8586驱动接入资料/src/Pcie8586.Driver/
# 采集卡独立驱动类库,被 Devices/Tests 引用
```
### 4.3 关键脚本
- `run.ps1`:发布 UI、可选执行单测、可选灌入种子数据、最后启动发布产物
- `publish.ps1`:单独发布 WPF 程序
- `SSPCTester.Seed/WriteQualifiedProjects.ps1`:生成演示项目
---
## 5. 配置与驱动切换
### 5.1 配置加载顺序
程序启动时配置来源按优先级叠加:
1. 内置默认配置
2. `SSPCTester.UI/appsettings.json`
3. `%LOCALAPPDATA%\SSPCTester\settings.json`
用户在设置页修改的路径、报告格式等,最终写到用户目录,不回写仓库里的 `appsettings.json`
### 5.2 当前切换策略
当前采用 **每类设备独立切换**
- `Devices:Sspc:UseMock`
- `Devices:PowerSupply:UseMock`
- `Devices:Load:UseMock`
- `Devices:Daq:UseMock`
- `Devices:Pci2312:UseMock`
`Devices:MockMode` 仅保留兼容旧配置用途,不应再作为新逻辑入口。
### 5.3 当前 `appsettings.json` 节选
```json
{
"Devices": {
"MockMode": false,
"Sspc": {
"UseMock": false,
"AutoConnect": true,
"PortName": "COM1",
"BaudRate": 9600,
"ModuleAddresses": [1, 2, 3]
},
"PowerSupply": {
"UseMock": false,
"AutoConnect": true,
"Host": "192.168.6.5",
"Port": 5025
},
"Load": {
"UseMock": false,
"AutoConnect": true,
"Host": "192.168.200.100",
"Port": 30000
},
"Daq": {
"UseMock": false,
"AutoConnect": true,
"LogicalDeviceId": 0,
"ChannelCount": 1,
"InputRange": "PlusMinus5V",
"ClockDivider": 1000,
"PreTriggerMs": 3,
"PostTriggerMs": 100,
"Channels": [
{ "PhysicalChannel": 0, "Role": "OutputVoltage", "Name": "输出电压", "Scale": 1.0, "Offset": 0.0, "IsCalibrated": true },
{ "PhysicalChannel": 1, "Role": "Unconfigured", "Name": "CH1", "Scale": 1.0, "Offset": 0.0, "IsCalibrated": false }
]
},
"Pci2312": {
"Enabled": true,
"UseMock": false,
"AutoConnect": true,
"DeviceId": 0,
"EmergencyInputChannel": 0,
"EmergencyInputActiveHigh": true,
"AlarmOutputChannel": 0,
"AlarmOutputActiveHigh": true,
"PollIntervalMs": 100
}
},
"Storage": {
"ProjectsRoot": "%LOCALAPPDATA%\\SSPCTester\\Projects"
},
"Report": {
"SavePath": "%LOCALAPPDATA%\\SSPCTester\\Reports",
"Format": "Pdf"
}
}
```
---
## 6. 设备接口
所有设备接口均为异步接口,默认支持 `CancellationToken`
### 6.1 公共连接接口
```csharp
public interface IDeviceConnection
{
bool IsConnected { get; }
string DisplayName { get; }
Task<bool> ConnectAsync(CancellationToken ct = default);
Task DisconnectAsync();
event EventHandler<bool>? ConnectionChanged;
}
```
### 6.2 SSPC
```csharp
public interface ISspc : IDeviceConnection
{
int ChannelCount { get; }
Task TurnOnAsync(int physicalSlot, CancellationToken ct = default);
Task TurnOffAsync(int physicalSlot, CancellationToken ct = default);
Task FlashAsync(int physicalSlot, int milliseconds, CancellationToken ct = default);
Task<bool> GetChannelStateAsync(int physicalSlot, CancellationToken ct = default);
Task<ChannelMeasurement> ReadMeasurementAsync(int physicalSlot, CancellationToken ct = default);
Task<IReadOnlyList<ChannelMeasurement>> ReadMeasurementsAsync(CancellationToken ct = default);
}
```
### 6.3 电源
```csharp
public interface IPowerSupply : IDeviceConnection
{
Task SetVoltageAsync(double volts, CancellationToken ct = default);
Task SetCurrentLimitAsync(double amps, CancellationToken ct = default);
Task OutputAsync(bool on, CancellationToken ct = default);
Task<(double volts, double amps)> ReadAsync(CancellationToken ct = default);
Task<string> QueryIdentityAsync(CancellationToken ct = default);
}
```
### 6.4 负载
```csharp
public readonly record struct PowerReading(double Volts, double Amps, double Watts);
public interface ILoad : IDeviceConnection
{
Task SetModeAsync(LoadMode mode, CancellationToken ct = default);
Task SetValueAsync(double value, CancellationToken ct = default);
Task InputAsync(bool on, CancellationToken ct = default);
Task<(double volts, double amps)> ReadAsync(CancellationToken ct = default);
Task<PowerReading> ReadPowerAsync(CancellationToken ct = default);
Task<string> QueryIdentityAsync(CancellationToken ct = default);
}
```
### 6.5 DAQ
```csharp
public interface IDaq : IDeviceConnection
{
Task<IReadOnlyList<DaqDeviceDescriptor>> EnumerateDevicesAsync(CancellationToken ct = default);
Task<CurveData> CaptureAsync(int[] channels, int sampleRateHz, double durationSec, CancellationToken ct = default);
Task<double[]> ReadInstantAsync(int[] channels, CancellationToken ct = default);
Task<CurveData> CaptureAroundActionAsync(
DaqActionCaptureRequest request,
Func<CancellationToken, Task> action,
CancellationToken ct = default);
event EventHandler<CurveSample>? SampleReceived;
}
```
`CaptureAroundActionAsync()` 是当前曲线测试的核心接口:
先进入预采集,再在触发点附近执行开关动作,以得到统一对齐的波形。
### 6.6 安全 DIO
```csharp
public interface ISafetyDio : IDeviceConnection
{
Task<bool> ReadInputAsync(int channel, CancellationToken ct = default);
Task WriteOutputAsync(int channel, bool on, CancellationToken ct = default);
}
```
当前真实实现为 `Pci2312SafetyDio`
- `ConnectAsync()` 调用 `PCI2312_CreateDevice(DeviceId)` 创建设备句柄。
- `ReadInputAsync(channel)` 调用 `PCI2312_GetDeviceDI()` 读取 0~15 路 DI。
- `WriteOutputAsync(channel, on)` 维护 16 路 DO 状态数组,并调用 `PCI2312_SetDeviceDO()` 一次性写出。
- `DisconnectAsync()` 调用 `PCI2312_ReleaseDevice()` 释放句柄。
`ConfigurableSafetyDio``Devices:Pci2312:UseMock``MockSafetyDio``Pci2312SafetyDio` 间切换。PCI2312 是否参与自动连接由 `Devices:Pci2312:Enabled``Devices:Pci2312:AutoConnect` 共同决定。
---
## 7. 核心业务逻辑
### 7.1 测试模块统一入口
`Logic/Testing` 中已经落地:
```csharp
public interface ITestModule
{
string Name { get; }
Task RunAsync(TestContext ctx, IProgress<TestProgress> progress, CancellationToken ct);
}
```
`TestContext` 当前持有:
- `Project`
- `ISspc`
- `IPowerSupply`
- `ILoad`
- `IDaq`
`TestRunner` 依据 `Project.Selection` 串行执行模块。
设备安全监控不属于 `ITestModule`,不会进入项目测试结果,也不会由 `TestRunner` 调度;它由 UI 层 `SafetyMonitorService` 在程序运行期持续维护。
### 7.2 浏览态 / 测试态
当前程序已实现两种应用状态:
- **浏览态**:左侧树显示全部项目,可自由切换
- **测试态**
- 只显示当前项目
- 顶部展示“测试进行中”状态条
- 可中止测试
- 设备连接视为当前项目独占
这一逻辑由 `MainViewModel.AppState` 控制。
### 7.3 基础测试
当前基础测试实现采用 `ISspc.ReadMeasurementAsync()` 直接读取每路电压/电流:
```text
TurnOnAsync(ch)
-> Delay
-> ReadMeasurementAsync(ch)
-> 记录 VoltageOn / CurrentOn
-> TurnOffAsync(ch)
-> WaitForStableOffAsync(ch)
-> 根据导通和关断稳态结果判定 Pass / Fail
```
说明:
- 不是旧文档中的 `Daq.ReadInstant()` 方案
- “关断是否稳定”通过 `BasicTestCriteria.WaitForStableOffAsync()` 判定
### 7.4 曲线测试
当前代码存在两套相关逻辑:
1. **Logic 模块批处理**`CurveTest.cs`
- 一次完成开通与关断两段采集
- 适用于测试模块整体执行
2. **UI 曲线页交互**`CurveTestViewModel`
- 已拆成两个独立按钮:
- `开启曲线测试`
- `关断曲线测试`
- 开/关曲线各自保存、各自绘图、各自维护视窗范围
当前页与弹窗的“起点 / 终点 / 默认”已经拆成两套独立状态:
- `RisingViewStartMs` / `RisingViewEndMs`
- `FallingViewStartMs` / `FallingViewEndMs`
这些值会写回 `CurveResultRow` 并持久化。
状态规则:
- 两半都没做:`Untested`
- 只完成一半:`Measured`
- 两半都完成后:才根据 4 个指标判 `Pass / Fail`
### 7.5 功率损耗
当前正式实现采用:
- `UDP5080` 读取输入端 `Vin / Iin`
- `IT87xx` 读取输出端 `Vout / Iout / Pout`
这是当前在用方案。
仓库中仍保留旧的 `PowerTestLegacy`DAQ 思路),但未作为正式模块注册。
### 7.6 保护功能
当前保护功能页和逻辑层已经按固定保护项落地,结果由 `ProtectRow` 持久化。`ProtectTestPlan` 负责初始化和刷新固定测试项:
- `跳闸`:触发条件默认 `1.5×额定电流`
- `短路`:触发条件默认 `输出短路`
- `过温`:触发条件默认 `≥85℃`
- `过压`:触发条件默认 `≥32V`
- `欠压`:触发条件默认 `≤22V`
- `限流`:触发条件默认 `≥1.2A`
保护功能数据分为两类:
- **自动获取**:对 `跳闸`、`过压`、`欠压`、`限流` 等可由电源读数支撑的项目,页面提供“测”按钮,调用 `IPowerSupply.ReadAsync()` 获取当前电压/电流并写入 `MeasuredValue`
- **人工观测**:对 `短路`、`过温` 等需要现场动作、仪表或人员观察的项目,由操作人员在 `MeasuredValue`、`Trigger` 等字段中填写观测记录。
判定口径:
- 最终判别标准为**人工判别**,不由程序自动计算合格/不合格。
- `JudgeMode` 默认值为 `人工判别`
- `Status` 由操作人员在表格中选择 `合格` / `不合格` / `未判定`
- `ProtectTest.RunAsync()` 只负责刷新测量值和进度状态;若某项已经被人工判定为 `Pass``Fail`,运行批量测试时会保留该人工判定结果。
### 7.7 设备安全监控
`SafetyMonitorService` 是当前急停/报警链路的中心,依赖:
- `ISafetyDio`:读取急停 DI、写报警灯 DO。
- `ISspc`:触发急停后逐路执行 `TurnOffAsync(1..24)`
- `IPowerSupply`:触发急停后执行 `OutputAsync(false)`,真实 UDP5080 命令为 `:OUTput OFF`
- `ILoad`:触发急停后执行 `InputAsync(false)`,真实 IT8702P 命令为 `INP OFF`
- `UiLogSink`:写入 UI 日志,便于现场追踪急停动作。
启动链路:
```text
App.ConfigureServices()
-> 注册 MockSafetyDio / Pci2312SafetyDio / ConfigurableSafetyDio
-> 注册 SafetyMonitorService
-> MainViewModel.Initialize()
-> ConnectConfiguredDevicesAsync()
-> SafetyMonitorService.Start()
```
运行链路:
```text
Timer(PollIntervalMs代码中限制 50~10000ms)
-> 自动连接 PCI2312若启用 AutoConnect
-> ReadInputAsync(EmergencyInputChannel)
-> 按 EmergencyInputActiveHigh 解释有效电平
-> 触发 HandleEmergencyAsync()
```
急停处理具有防重入保护:`_gate` 和 `_handlingEmergency` 避免重复并发关断。每个设备的关断失败会单独记录日志,不阻断后续设备的关断尝试。
主窗口顶部状态区会展示:
- 报警灯动态图标:绑定 `AlarmLampActive`
- 急停/重置按钮:绑定 `ToggleEmergencyAlarmCommand`
- 安全状态文本:来自 `SafetyMonitorService.StatusText / DetailText`
- 设备面板中的 `报警/急停` 连接状态:来自 `ISafetyDio.IsConnected`
### 7.8 报告
当前报告支持:
- PDF
- Word
- PDF + Word
报告特性:
- 基于项目与勾选项动态生成
- 曲线插图由 `CurveImageRenderer` 生成
- 报告文件名不是固定 `report.docx`,而是动态解析后输出
- 报告页通过 `WebView2` 预览 PDF
---
## 8. 数据存储
### 8.1 项目目录
每个项目一个目录,目录根路径由 `Storage:ProjectsRoot` 决定。
典型内容:
- `project.json`
- `curves/`
- 生成出的 PDF / Word 报告
### 8.2 项目对象
`Project` 当前持久化内容包括:
- DUT 信息
- 测试站点信息
- 测试项勾选
- 报告配置
- 基础测试、曲线测试、功率损耗、保护功能结果
- 曲线阈值
- 四页测试说明文本
### 8.3 波形存储格式
波形不是简单的 JSON而是
- `curves/*.bin`float32 二进制采样数据
- `curves/*.json`:元数据
元数据包含:
- 采样率
- 触发点位置
- 通道角色/名称/单位
- 标定参数
### 8.4 旧数据兼容
`CurveResultRow` 中保留了旧字段:
- `ViewStartMs`
- `ViewEndMs`
新逻辑优先使用:
- `RisingViewStartMs / RisingViewEndMs`
- `FallingViewStartMs / FallingViewEndMs`
缺失时会回退到旧字段,兼容老项目。
---
## 9. 运行与发布
### 9.1 本地运行
推荐命令:
```powershell
PowerShell -ExecutionPolicy Bypass -File .\run.ps1
```
该脚本默认行为:
1. `dotnet publish` UI 到 `publish\win-x64`
2. 可选执行测试
3. 可选执行种子数据生成
4. 直接启动 `publish\win-x64\SSPCTester.UI.exe`
### 9.2 常用参数
- `-Test`:执行 `SSPCTester.Tests`
- `-Seed`:执行 `SSPCTester.Seed`
- `-CleanSeed`:清空项目目录后重新灌入种子数据
- `-NoLaunch`:只发布不启动
### 9.3 发布
推荐命令:
```powershell
PowerShell -ExecutionPolicy Bypass -File .\publish.ps1
```
当前默认发布参数是:
- `Release`
- `win-x64`
- `SelfContained = true`
- `SingleFile = false`
说明:
- 当前脚本明确没有走 WPF 单文件发布默认方案
- 发布时会检查 `ACTS1000_64.dll` 是否存在
- PCI2312 真设备模式还需要 `PCI2312_64.dll` 可由进程加载;当前发布脚本未做该 DLL 的存在性检查
### 9.4 运行环境
源码构建至少需要:
- Windows x64
- .NET 8 SDK x64
- WebView2 Runtime
- 真卡模式下的 PCIe8586 / PCI2312 厂商驱动与 x64 DLL
若只运行现成发布版,则至少需要满足发布产物依赖和本机驱动/DLL 条件。
---
## 10. 当前状态与后续工作
### 10.1 已完成
- WPF 主程序骨架、主题资源、页面导航
- 浏览态 / 测试态切换
- 项目新建、加载、保存
- 基础测试、曲线测试、功率损耗、保护功能页和结果记录
- PDF / Word 报告生成
- 真/假设备可按设备粒度切换
- 实际 SSPC / 电源 / 负载 / PCIe8586 / PCI2312 驱动接入代码
- PCI2312 急停输入轮询、报警输出、软件急停、状态重置和设备关断联动
### 10.2 待统一 / 待完善
- 功率损耗旧版 `PowerTestLegacy` 仍在仓库,后续应明确去留
- 曲线弹窗窗口已实现,但当前主页面尚未提供入口按钮
- 报告生成对新旧曲线视窗字段的使用口径后续建议统一
- PCI2312 真设备链路需要在现场确认 DI/DO 接线、电平有效性、报警灯供电方式和 DLL 随发布产物部署方式
---
## 11. 风险与注意事项
1. **DAQ 仍是最高风险点**:厂商 DLL、设备 ID、采样参数、输入量程和触发时序都依赖现场。
2. **Modbus 地址和端口仍需现场核实**:虽然当前实现已支持 3 模块映射,但设备地址/串口号应视现场配置为准。
3. **电源与负载真实驱动已接入,但控制命令支持度需按实物验证**
4. **PCI2312 急停报警链路依赖现场接线和 DLL 部署**DI/DO 通道号、高/低有效配置、报警灯供电、`PCI2312_64.dll` 位数和搜索路径都必须逐项核实。
5. **软件安全链路不能替代硬件安全回路**`SafetyMonitorService` 通过轮询和软件命令下发关断,适合作为上位机联动保护;最终急停/互锁仍应由硬件电气回路兜底。
6. **状态重置必须确认急停输入已复位**:当前代码在 DI 仍有效时拒绝关闭报警灯,避免误复位。
7. **所有长流程应贯穿 `CancellationToken`**,中止后优先保证设备回到安全状态。
8. **示波器不纳入软件控制**,仅作为线下校准基准。
9. **任何涉及数据模型持久化格式的修改,都要考虑旧项目兼容**
---
## 12. 维护建议
1. 改接口前,先同步修改 `Devices.Interfaces`、实现类、DI 装配和本文档。
2. 改项目结构前,先检查 `run.ps1`、`publish.ps1`、`Seed`、测试项目是否受影响。
3. 改曲线页前,注意当前已经有“主页面 + 弹窗 + 报告图”的三处视窗相关逻辑。
4. 改报告前,确认 `ReportViewModel`、`Logic/Report`、`WebView2` 预览链路同时保持可用。
5. 改设备安全链路前,先确认 `ISafetyDio`、`Pci2312SafetyDio`、`ConfigurableSafetyDio`、`SafetyMonitorService`、主窗口急停按钮和设置页 PCI2312 配置同步调整。
6. 若发现文档内容再次与代码偏离,应优先更新本文档,而不是继续在过时约束上开发。