SSPC-Tester/SSPCTester.Logic/Testing/BasicTestCriteria.cs

55 lines
1.9 KiB
C#
Raw Normal View History

using System.Diagnostics;
using SSPCTester.Devices.Interfaces;
namespace SSPCTester.Logic.Testing;
/// <summary>基础通断测试的统一判定规则。</summary>
public static class BasicTestCriteria
{
public const double OnVoltageThreshold = 1.0;
public const double OffVoltageThreshold = 0.5;
public const int SwitchSettleDelayMs = 1_000;
public const int OffSettleTimeoutMs = 2_000;
public const int OffInitialDelayMs = 100;
public const int OffSampleIntervalMs = 100;
public const int RequiredStableOffSamples = 2;
public static bool IsOn(double voltage) => voltage > OnVoltageThreshold;
public static bool IsOff(double voltage) => Math.Abs(voltage) < OffVoltageThreshold;
/// <summary>
/// 等待关断电压稳定。连续多次低于阈值才确认关断,避免旧帧和瞬时噪声造成误判。
/// </summary>
public static async Task<OffStateResult> WaitForStableOffAsync(
ISspc sspc,
int channel,
CancellationToken ct = default)
{
await Task.Delay(OffInitialDelayMs, ct).ConfigureAwait(false);
var stopwatch = Stopwatch.StartNew();
int stableSamples = 0;
ChannelMeasurement? latest = null;
while (stopwatch.ElapsedMilliseconds < OffSettleTimeoutMs)
{
latest = await sspc.ReadMeasurementAsync(channel, ct).ConfigureAwait(false);
stableSamples = IsOff(latest.Voltage) ? stableSamples + 1 : 0;
if (stableSamples >= RequiredStableOffSamples)
return new OffStateResult(true, latest, stopwatch.Elapsed);
await Task.Delay(OffSampleIntervalMs, ct).ConfigureAwait(false);
}
latest ??= await sspc.ReadMeasurementAsync(channel, ct).ConfigureAwait(false);
return new OffStateResult(false, latest, stopwatch.Elapsed);
}
}
public sealed record OffStateResult(
bool IsStableOff,
ChannelMeasurement Measurement,
TimeSpan Elapsed);