SSPC-Tester/SSPCTester.UI/Services/SafetyMonitorService.cs

427 lines
17 KiB
C#
Raw Permalink Normal View History

using System.Diagnostics;
using System.IO;
using Microsoft.Extensions.Logging;
using Microsoft.Extensions.Options;
using SSPCTester.Devices.Config;
using SSPCTester.Devices.Interfaces;
namespace SSPCTester.UI.Services;
public sealed class SafetyMonitorService : IDisposable
{
private readonly ISafetyDio _safetyDio;
private readonly IPowerSupply _power;
private readonly ILoad _load;
private readonly ISspc _sspc;
private readonly DeviceOptions _options;
private readonly UiLogSink _log;
private readonly ILogger<SafetyMonitorService> _logger;
private readonly SemaphoreSlim _gate = new(1, 1);
private readonly string _traceLogPath;
private readonly object _traceLock = new();
private Timer? _timer;
private bool _handlingEmergency;
private bool _softwareEmergencyActive;
2026-07-09 10:47:46 +08:00
private bool _hardwareEmergencyLatched;
private bool _disposed;
private long _pollSequence;
private long _pollGateBusyCount;
private string? _lastStatusSnapshot;
private string? _lastPollSnapshot;
public SafetyMonitorService(
ISafetyDio safetyDio,
IPowerSupply power,
ILoad load,
ISspc sspc,
IOptions<DeviceOptions> options,
UiLogSink log,
ILogger<SafetyMonitorService> logger)
{
_safetyDio = safetyDio;
_power = power;
_load = load;
_sspc = sspc;
_options = options.Value;
_log = log;
_logger = logger;
string logDir = Path.Combine(
Environment.GetFolderPath(Environment.SpecialFolder.LocalApplicationData),
"SSPCTester",
"Logs");
Directory.CreateDirectory(logDir);
_traceLogPath = Path.Combine(logDir, $"safety-trace-{DateTime.Now:yyyyMMdd-HHmmss}.log");
Trace($"Safety trace started. UseMock={_options.Pci2312.UseMock}, AutoConnect={_options.Pci2312.AutoConnect}, Enabled={_options.Pci2312.Enabled}, PollIntervalMs={_options.Pci2312.PollIntervalMs}");
}
public bool IsEmergencyActive { get; private set; }
public bool IsAlarmOutputOn { get; private set; }
public string StatusText { get; private set; } = "设备故障";
public string DetailText { get; private set; } = "设备安全监控未启动";
public event EventHandler? StatusChanged;
public void Start()
{
if (_timer is not null) return;
var options = _options.Pci2312;
Trace($"Start() called. Enabled={options.Enabled}, AutoConnect={options.AutoConnect}, DeviceId={options.DeviceId}, DI={options.EmergencyInputChannel}, DO={options.AlarmOutputChannel}, PollIntervalMs={options.PollIntervalMs}");
if (!options.Enabled)
{
SetStatus(false, false, "设备故障", "PCI2312 安全监控未启用");
return;
}
2026-07-09 10:47:46 +08:00
int interval = Math.Clamp(options.PollIntervalMs, 50, 10000);
_timer = new Timer(OnTimer, null, TimeSpan.Zero, TimeSpan.FromMilliseconds(interval));
SetStatus(false, false, "设备正常", "正在监控 PCI2312 急停输入");
_log.Add(UiLogLevel.Info, $"安全观测日志已启用:{_traceLogPath}");
}
public async Task TriggerSoftwareEmergencyAsync(CancellationToken ct = default)
{
var sw = Stopwatch.StartNew();
Trace("TriggerSoftwareEmergencyAsync enter.");
await _gate.WaitAsync(ct).ConfigureAwait(false);
try
{
_softwareEmergencyActive = true;
_handlingEmergency = true;
SetStatus(true, IsAlarmOutputOn, "软件急停已触发", "正在执行软件急停安全关断");
_log.Add(UiLogLevel.Error, "软件触发报警急停,开始执行报警灯、电源、负载关断。");
await EnsureSafetyDioConnectedAsync(ct).ConfigureAwait(false);
await SetAlarmOutputAsync(true, ct).ConfigureAwait(false);
await TryShutdownSspcAsync().ConfigureAwait(false);
await TryShutdownPowerAsync().ConfigureAwait(false);
await TryShutdownLoadAsync().ConfigureAwait(false);
SetStatus(true, true, "软件急停已触发", "报警灯已接通SSPC 通道已全部关断,电源输出和负载输入已发送关闭指令");
Trace($"TriggerSoftwareEmergencyAsync success in {sw.ElapsedMilliseconds}ms.");
}
catch (Exception ex)
{
_softwareEmergencyActive = false;
_handlingEmergency = false;
_logger.LogError(ex, "Software emergency shutdown failed.");
_log.Add(UiLogLevel.Error, $"软件急停执行异常:{ex.Message}");
SetStatus(true, IsAlarmOutputOn, "设备故障", ex.Message);
Trace($"TriggerSoftwareEmergencyAsync failed in {sw.ElapsedMilliseconds}ms. {ex.GetType().Name}: {ex.Message}");
throw;
}
finally
{
_gate.Release();
}
}
public async Task<SafetyResetResult> ResetAsync(CancellationToken ct = default)
{
await _gate.WaitAsync(ct).ConfigureAwait(false);
try
{
return await ResetCoreAsync(ct).ConfigureAwait(false);
}
finally
{
_gate.Release();
}
}
private async Task<SafetyResetResult> ResetCoreAsync(CancellationToken ct)
{
Trace("ResetCoreAsync enter.");
var options = _options.Pci2312;
await EnsureSafetyDioConnectedAsync(ct).ConfigureAwait(false);
if (await IsEmergencyInputActiveAsync(options, ct).ConfigureAwait(false))
{
const string message = "硬件急停按钮仍处于触发状态,无法执行状态重置。请先旋转或释放设备上的急停按钮,确认急停输入复位后再重试。";
SetStatus(true, IsAlarmOutputOn, "急停已触发", message);
Trace("ResetCoreAsync blocked: emergency input still active.");
return new SafetyResetResult(false, message);
}
await SetAlarmOutputAsync(false, ct).ConfigureAwait(false);
_softwareEmergencyActive = false;
2026-07-09 10:47:46 +08:00
_hardwareEmergencyLatched = false;
_handlingEmergency = false;
SetStatus(false, false, "设备正常", "急停状态已重置,报警灯已关闭,正在监控 PCI2312 输入");
Trace("ResetCoreAsync success.");
return new SafetyResetResult(true, "急停状态已重置。");
}
private void OnTimer(object? state)
{
if (_disposed) return;
_ = PollAsync();
}
private async Task PollAsync()
{
if (!await _gate.WaitAsync(0).ConfigureAwait(false))
{
long skipped = Interlocked.Increment(ref _pollGateBusyCount);
if (skipped % 20 == 0)
Trace($"PollAsync skipped by gate contention. skipped={skipped}");
return;
}
try
{
long seq = Interlocked.Increment(ref _pollSequence);
var options = _options.Pci2312;
if (!options.Enabled) return;
if (options.AutoConnect && !_safetyDio.IsConnected)
{
Trace($"Poll#{seq}: attempting auto connect for safety DIO.");
await _safetyDio.ConnectAsync().ConfigureAwait(false);
}
bool active = await IsEmergencyInputActiveAsync(options, CancellationToken.None).ConfigureAwait(false);
string snapshot = $"poll={seq},active={active},handling={_handlingEmergency},soft={_softwareEmergencyActive},latched={_hardwareEmergencyLatched},emergency={IsEmergencyActive},alarm={IsAlarmOutputOn},dioConnected={_safetyDio.IsConnected}";
if (!string.Equals(_lastPollSnapshot, snapshot, StringComparison.Ordinal))
{
_lastPollSnapshot = snapshot;
Trace($"Poll snapshot: {snapshot}");
}
if (active)
{
2026-07-09 10:47:46 +08:00
_hardwareEmergencyLatched = true;
Trace($"Poll#{seq}: branch=ACTIVE -> HandleEmergencyAsync");
await HandleEmergencyAsync().ConfigureAwait(false);
}
2026-07-09 10:47:46 +08:00
else if (_hardwareEmergencyLatched)
{
Trace($"Poll#{seq}: branch=HardwareLatchedClear -> ClearHardwareEmergencyAsync");
2026-07-09 10:47:46 +08:00
await ClearHardwareEmergencyAsync(options).ConfigureAwait(false);
}
else if (_softwareEmergencyActive)
{
Trace($"Poll#{seq}: branch=SoftwareActiveWaitReset");
SetStatus(true, IsAlarmOutputOn, "软件急停已触发", "等待状态重置,电源和负载不会自动恢复");
}
else if (IsEmergencyActive || IsAlarmOutputOn)
{
Trace($"Poll#{seq}: branch=CleanupByStatus -> ClearHardwareEmergencyAsync");
2026-07-09 10:47:46 +08:00
await ClearHardwareEmergencyAsync(options).ConfigureAwait(false);
}
else
{
SetStatus(false, false, "设备正常", $"DI{options.EmergencyInputChannel} 未触发");
}
}
catch (Exception ex)
{
_logger.LogWarning(ex, "Safety monitor poll failed.");
SetStatus(IsEmergencyActive, IsAlarmOutputOn, "设备故障", ex.Message);
Trace($"PollAsync failed. {ex.GetType().Name}: {ex.Message}");
}
finally
{
_gate.Release();
}
}
private async Task HandleEmergencyAsync()
{
if (_handlingEmergency)
{
Trace("HandleEmergencyAsync skipped because _handlingEmergency=true.");
return;
}
var sw = Stopwatch.StartNew();
_handlingEmergency = true;
SetStatus(true, IsAlarmOutputOn, "急停已触发", "正在执行安全关断");
_log.Add(UiLogLevel.Error, "检测到急停输入接通,开始执行报警灯、电源、负载关断。");
Trace("HandleEmergencyAsync begin.");
try
{
var step = Stopwatch.StartNew();
await SetAlarmOutputAsync(true, CancellationToken.None).ConfigureAwait(false);
Trace($"HandleEmergencyAsync step SetAlarmOutputAsync OK in {step.ElapsedMilliseconds}ms.");
step.Restart();
await TryShutdownSspcAsync().ConfigureAwait(false);
Trace($"HandleEmergencyAsync step TryShutdownSspcAsync done in {step.ElapsedMilliseconds}ms.");
step.Restart();
await TryShutdownPowerAsync().ConfigureAwait(false);
Trace($"HandleEmergencyAsync step TryShutdownPowerAsync done in {step.ElapsedMilliseconds}ms.");
step.Restart();
await TryShutdownLoadAsync().ConfigureAwait(false);
Trace($"HandleEmergencyAsync step TryShutdownLoadAsync done in {step.ElapsedMilliseconds}ms.");
SetStatus(true, true, "急停已触发", "报警灯已接通SSPC 通道已全部关断,电源输出和负载输入已发送关闭指令");
Trace($"HandleEmergencyAsync success in {sw.ElapsedMilliseconds}ms.");
}
catch (Exception ex)
{
_logger.LogError(ex, "Emergency shutdown failed.");
_log.Add(UiLogLevel.Error, $"急停关断执行异常:{ex.Message}");
SetStatus(true, IsAlarmOutputOn, "设备故障", ex.Message);
_handlingEmergency = false;
Trace($"HandleEmergencyAsync failed in {sw.ElapsedMilliseconds}ms. {ex.GetType().Name}: {ex.Message}");
}
}
2026-07-09 10:47:46 +08:00
private async Task ClearHardwareEmergencyAsync(Pci2312Options options)
{
var sw = Stopwatch.StartNew();
Trace("ClearHardwareEmergencyAsync begin.");
2026-07-09 10:47:46 +08:00
if (IsAlarmOutputOn)
await SetAlarmOutputAsync(false, CancellationToken.None).ConfigureAwait(false);
_handlingEmergency = false;
_softwareEmergencyActive = false;
_hardwareEmergencyLatched = false;
SetStatus(false, false, "设备正常", $"DI{options.EmergencyInputChannel} 已复位,硬件急停已解除,报警灯已关闭,设备输出不会自动恢复");
_log.Add(UiLogLevel.Info, "硬件急停输入已复位,软件急停状态和报警灯已自动解除。");
Trace($"ClearHardwareEmergencyAsync success in {sw.ElapsedMilliseconds}ms.");
2026-07-09 10:47:46 +08:00
}
private async Task TryShutdownSspcAsync()
{
try
{
if (!_sspc.IsConnected && _options.Sspc.AutoConnect)
{
Trace("TryShutdownSspcAsync: auto-connecting SSPC.");
await _sspc.ConnectAsync().ConfigureAwait(false);
}
if (_sspc.IsConnected)
{
for (int ch = 1; ch <= _sspc.ChannelCount; ch++)
{
try { await _sspc.TurnOffAsync(ch).ConfigureAwait(false); }
catch (Exception ex) { _logger.LogWarning(ex, "急停关断 SSPC CH{Ch} 失败。", ch); }
}
_log.Add(UiLogLevel.Warning, $"SSPC 全部 {_sspc.ChannelCount} 个通道已发送关断指令。");
}
else
{
_log.Add(UiLogLevel.Warning, "SSPC 未连接,跳过通道关断。");
}
}
catch (Exception ex)
{
_logger.LogWarning(ex, "SSPC 批量关断失败。");
_log.Add(UiLogLevel.Error, $"SSPC 通道批量关断失败:{ex.Message}");
Trace($"TryShutdownSspcAsync failed. {ex.GetType().Name}: {ex.Message}");
}
}
private async Task TryShutdownPowerAsync()
{
try
{
if (!_power.IsConnected && _options.PowerSupply.AutoConnect)
{
Trace("TryShutdownPowerAsync: auto-connecting power supply.");
await _power.ConnectAsync().ConfigureAwait(false);
}
if (_power.IsConnected)
await _power.OutputAsync(false).ConfigureAwait(false);
_log.Add(UiLogLevel.Warning, "UDP5080 电源输出已发送关闭指令。");
}
catch (Exception ex)
{
_logger.LogWarning(ex, "Power shutdown failed.");
_log.Add(UiLogLevel.Error, $"UDP5080 电源关闭失败:{ex.Message}");
Trace($"TryShutdownPowerAsync failed. {ex.GetType().Name}: {ex.Message}");
}
}
private async Task TryShutdownLoadAsync()
{
try
{
if (!_load.IsConnected && _options.Load.AutoConnect)
{
Trace("TryShutdownLoadAsync: auto-connecting load.");
await _load.ConnectAsync().ConfigureAwait(false);
}
if (_load.IsConnected)
await _load.InputAsync(false).ConfigureAwait(false);
_log.Add(UiLogLevel.Warning, "IT8702P 负载输入已发送关闭指令。");
}
catch (Exception ex)
{
_logger.LogWarning(ex, "Load shutdown failed.");
_log.Add(UiLogLevel.Error, $"IT8702P 负载关闭失败:{ex.Message}");
Trace($"TryShutdownLoadAsync failed. {ex.GetType().Name}: {ex.Message}");
}
}
private async Task<bool> IsEmergencyInputActiveAsync(Pci2312Options options, CancellationToken ct)
{
bool value = await _safetyDio.ReadInputAsync(options.EmergencyInputChannel, ct).ConfigureAwait(false);
return options.EmergencyInputActiveHigh ? value : !value;
}
private async Task SetAlarmOutputAsync(bool on, CancellationToken ct)
{
var options = _options.Pci2312;
bool outputValue = options.AlarmOutputActiveHigh ? on : !on;
await _safetyDio.WriteOutputAsync(options.AlarmOutputChannel, outputValue, ct).ConfigureAwait(false);
IsAlarmOutputOn = on;
}
private async Task EnsureSafetyDioConnectedAsync(CancellationToken ct)
{
var options = _options.Pci2312;
if (!options.Enabled)
throw new InvalidOperationException("PCI2312 安全输入输出未启用,无法控制报警灯。");
if (!_safetyDio.IsConnected)
{
Trace("EnsureSafetyDioConnectedAsync: connecting safety DIO.");
await _safetyDio.ConnectAsync(ct).ConfigureAwait(false);
}
}
private void SetStatus(bool emergencyActive, bool alarmOutputOn, string statusText, string detailText)
{
string snapshot = $"emergency={emergencyActive},alarm={alarmOutputOn},status={statusText},detail={detailText}";
if (!string.Equals(_lastStatusSnapshot, snapshot, StringComparison.Ordinal))
{
_lastStatusSnapshot = snapshot;
Trace($"SetStatus changed: {snapshot}");
}
IsEmergencyActive = emergencyActive;
IsAlarmOutputOn = alarmOutputOn;
StatusText = statusText;
DetailText = detailText;
StatusChanged?.Invoke(this, EventArgs.Empty);
}
public void Dispose()
{
Trace("Dispose() called. Safety monitor disposed.");
_disposed = true;
_timer?.Dispose();
_gate.Dispose();
}
private void Trace(string message)
{
string line = $"{DateTime.Now:yyyy-MM-dd HH:mm:ss.fff} [T{Environment.CurrentManagedThreadId}] {message}{Environment.NewLine}";
try
{
lock (_traceLock)
{
File.AppendAllText(_traceLogPath, line);
}
}
catch
{
// Temporary diagnostic trace should never break runtime behavior.
}
}
}
public sealed record SafetyResetResult(bool Success, string Message);